Electrical installation
4.6 Power connections
Drive converter cabinet units
56 Operating Instructions, 10/2008, A5E00288214A
Direction of motor rotation
With induction machines with a clockwise phase sequence (looking at the drive shaft), the
motor must be connected to the cabinet unit as follows.
Table 4- 3 Cabinet unit and motor connection terminals
Cabinet unit (connection terminals) Motor (connection terminals)
U2/T1 U
V2/T2 V
W2/T3 W
In contrast to the connection for the clockwise phase sequence, two phases have to be
reversed with a counter-clockwise phase sequence (looking at the drive shaft).
Note
If an incorrect rotating field was connected when the cables were installed, and the rotating
field cannot be corrected by swapping the motor cables, it can be corrected when
commissioning the drive via p1821 (rotating field direction reversal) by changing the rotating
field and thus enabling a direction reversal (see section "Functions, Monitoring and
protective functions / Direction reversal").
With motors that can be operated in a star/delta configuration, the windings must be checked
to ensure that they have been connected properly. Please refer to the relevant
documentation for the motor and note the required insulation voltage for operating the
cabinet unit.